Glen Allen & Co
Communications Equipment
Contact Us
Products
Home
Fall Protection
Outside Plant
Power Inverter
MQ Power Generator
Valere Compact DC Power Generator
Philtek Inverter
Power Equipment
Power Battery
Fisher TW-7700 Digital Line Tracer
Fisher XLT-16 Liquid & Gas Leak Detector
Fisher Labs Price List
Alcoa Fusion Splicer
DBI Sala Safety
DBI Sala Data Sheets
Protecta Data Sheets
Snap-Ins
Lugs
Ground Bars
Quazite Data Sheets
Polymer Concrete
Quazite Drawings
Grounding
DDB Unlimited Outdoor Cabinet
Tower Accessories
Tower Components
Towers
Wireless LAN
Network Equipment
Servers Workstations
Test Equipment
Complete List
Manufacturers Unipower
Telect
GUISYS
DBI Sala Fall Protection
DBI Sala Catalog
RAD Data Sheets
Newton Instruments
Fisher
Wilcom
Paragon
Site Advantage
Plantronics
Strongwell Quazite
Times Microwave
RAD
SendFar Wireless
Fibre Conn Assemblies
Sun Microsystems
Peco II
Arnco
Trimm
HD Telecom
Windsor
Complete List
Support
Contact US
Connector Installation
Cable Loss Table
White Papers



Philtek HPRi 3 Phase Modular Inverter System

  • 48 VDC Input

  • 90 kVA to 180 kVA

  • 277/480 VAC 3 Phase

  • Expansion and Redundancy
Inverter Modules “Plug and Play”
- 10 KVA output each
- High frequency PWM technology, quiet operation
- “Hot Pluggable”, allows installation or removal of modules
without de-energizing the system
- Output compatible with Active Power Factor Corrected AC
Loads
Static Bypass Switch and Controller
- Output power rating self configured, 2 mSec transfer time
- Microprocessor Controlled with LCD display and Industrial
style LED Mimic Diagram
- User configured to operate in the On-line ( Inverter preferred )
or the Off-line (AC line preferred ) mode
- Provides an additional level of redundancy when operated in
the On-line Mode
- Plug in modular construction, can be removed or installed with
no output interruption during Maintenance Bypass
- Optional RS-232 Communication Port available
AC Power Plant
- Constructed of heavy duty 23” racks
- Make Before Break Maintenance Bypass Switch provides
uninterrupted output during bypass
- AC line Circuit Breaker for overload protection during Static
Bypass
- Fully enclosed AC and DC power bus bars, pre-wired to
terminal blocks for external connections
- Inverter docking trays provide easy plug in and removal of
Inverter Modules
- CSA Certification pending
- UL 1778 Certification pending

Specifications
DC Input   Bypass AC Input  
Nominal 48 V Connection 4 wires (Y) + Gnd
Range 42 to 60 V Voltage 277/480V 3 Phase 60 Hz
Current See Table Current Same as output current
AC Output     see Table
Power See Table Static Bypass Switch  
Connection 4 wires (Y) + Gnd Transfer Time 2 mSec typical
Voltage 277/480V 3 Phase 60 Hz   4 mSec maximum
Regulation ± 1% Voltage Tolerance ± 10 %
Dynamic Regulation:   Frequency Tolerance ± 1.5 Hz
100 % step load ± 4% Overload: 120 % for 10 Minutes
Recovery < 8 mSec   1000 % for 8 ms
Efficiency 84 % to 87% Environmental  
Distortion ( linear load ) < 1.0 % THD Temperature 0º C to 40º C
Non Linear Load Capability Up to 100 % Humidity 95 % RH
Active P.F. Corrected Loads Compatible Cooling Forced Air with temperature
Load Power Factor ( PF ) 0.8   Controlled Fans
Frequency Tolerance ± 0.1 % free running Inverter Modules  
Overload 120 % for 10 minutes Output Model #
Synchronization:   10 kVA 277 Vac 1? HPRi-INV-10K-48-E
Range ± 1.5 Hz Weight 320 Lbs
Rate 1 Hz per Sec    

Inverter System 48 VDC input 277/480 VAC 60 Hz 3 Phase Output
Output VA @ 0.8 PF 90,000 VA 120,000 VA 150,000 VA
*AC Power Plant + Controller Model # HPRi 180K-48-3E+3R3E HPRi 180K-48-3E+4R3E HPRi 180K-48-3E+5R3E
Inverter Modules Required 9 x 10 kVA 12 x 10 kVA 15 x 10 kVA
AC Output Current per Phase 109 Amp AC 145 Amp AC 189 Amp AC
DC Input Current @ 42 V 3 x 672 Amp DC 4 x 672 Amp DC 5 x 672 Amp DC
AC Power Plant Racks 4 5 6
Overall Dim. W”xD”xH” 98 x 29 x 84 122.5 x 29 x 84 147 x 29 x 84
Total Weight ( Net ) 4,205 Lbs. 5,460 Lbs. 6,715 Lbs.

Inverter System 48 VDC input 277/480 VAC 60 Hz 3 Phase Output
Output VA @ 0.8 PF 180,000 VA 180,000 VA N+1
AC Power Plant + Controller Model # HPRi 180K-48-3E+6R3E HPRi 180K-48-3E+7R3E
Inverter Modules Required 18 x 10 kVA 21 x 10 kVA
AC Output Current per Phase 217 Amp AC 217 Amp AC
DC Input Current @ 42 V 6 x 672 Amp DC 7 x 672 Amp DC
AC Power Plant Racks 7 8
Overall Dim. W”xD”xH” 171.5 x 29 x 84 196 x 29 x 84
Total Weight ( Net ) 7,970 Lbs. 9,225 Lbs.